All combustible mantel surrounds and shelves must be kept at least 12 inches from the opening of your fireplace top and sides.
Gas fireplace insert clearance to combustibles.
For instance in the case of firerock building materials the minimum clearance to combustibles and framing from the firebox and smoke chamber is 1 inch.
For mantel clearances see figure 9 on page 1.
This article gives typical clearance distance requirements between the termination cap of a gas fireplace or fireplace insert and other building or site features such as windows doors other mechanical system components air intakes.
The insert is zero clearance approved so it can be framed without adding air gaps or spacing on the sides and top of the unit.
This duluth forge full size 400 series vent this duluth forge full size 400 series vent free zero clearance fireplace insert allows you to build a custom fireplace for your home.
Clearances refer to how far materials have to be from your fireplace.
Why do contractors architects and homebuyers trust heatilator.
Rigid pipe venting arrangements vertical terminations.
2114 3 masonry built fireplaces 4114 3 10 all combustible mantels and similar trim shall be kept at least 6 inches from the fireplace opening.
Gas fireplace direct vent termination cap clearance distances clearances between the gas fireplace exhaust vent and other building components or features.
Wood framing drywall touching the back and sides of the unit without fear of heat damage.
P36 p36e gas fireplace vent must be supported at offsets.
Most zero clearance fireplaces can have combustible materials e g.
Combustible material includes all wood trim framing mantels and anything else that can ignite and burn.
In addition if the side panels of your mantel project more than 1 1 2 inches from the fireplace facing you will need additional clearance equal to this projection.
Because we mix value with dependability.
Each 1 8 inch that trim or another combustible material protrudes requires an extra inch of clearance.
Established in 1927 heatilator has built a long standing reputation for providing quality dependable hearth products at unbeatable values.
Clearances from the top of the fireplace opening to the ceiling should not be less than 36.
Clearances vary by manufacturer and quality of materials used.
Maintain clearances to combustibles.
Heatilator fireplaces and inserts.
Figure 6 minimum clearance for combustible to wall minimum 16 from side wall example minimum clearance to combustible materials top left and right sides bottom and rear front 36 6 0 36.
Firestops are required at each floor level and whenever passing through a wall.
All fireplaces should have a noncombustible hearth extension.