Variable primary flow in bypass mode system flow below chiller min flow 250 gpm variable primary flow at 25 system load two way valves control capacity by varying flow of water in coils per chiller system load 50 tons 176kw 50tons 176 kw primary bypass flow 250 gpm 95 l s 150 gpm 9 5 l s delta t 12 of 6 7 oc 100 gpm 44 ºf 6.
Flow diagram chilled water system.
B primary chilled water pumps p 1 and p 2 shall be sized for the pressure.
2 12 3 central chilled water plant flow diagram.
Chilled water system equations evaporator and condenser flow rates sponsored links in a chilled water system the water is cooled down to 40 45 o f 4 7 o c by an centralized evaporator distributed throughout the building in pipes and connected locally to air condition cooling units wherever needed.
A more complex chilled water cooling system configuration can consist of multiple chillers multiple pumps cooling towers heat exchangers and all sorts of valves to redirect flow according to the heat load inside of the building.
The single most common problem in chiller piping installations is lack of chilled water flow caused by inadequate system venting.
The process fluid absorbs heat from what is being cooled and then goes through the chiller where the heat is removed from the fluid and transferred to the ambient air.
Every hvac system design should start with a single line flow diagram in the conceptual schematic phase.
Pressure drop between tees will determine flow to terminal unit water always follows path of least resistance.
Require two chillers to meet the cooling load.
The result is repeated flow alarms when the flow switch that is installed in the chiller opens the control circuit stops the chiller and sets the alarm.
At this early stage of the building program the design engineer can write a sequence of operation even if the designer has not firmed up the chilled water system capacity.
A the above arrangement shall be used for chilled water systems that.
Chilled water cooling systems.
Figure below shows the schematic of the constant flow rate primary system.
Chilled water trade names total comfort solution ultimate comfort systems zcooling domestic cold water chilled water trade names total comfort solution zheating domestic hot water.
Chilled water flow through the cooling coil is restricted in response to supply air temperatures to the space but the total quantity returned to the chiller remains constant.
If the flow rate in the secondary side is low then some chilled water will flow into the secondary and some will recirculate back to the chillers.
Industrial water or glycol chiller systems contain two main circuits.
Next we ll talk about a couple of different chilled water system configurations.